LC1F630
- delivery time60 days
- Quantity
Range | TeSys |
---|---|
Range of product | TeSys F |
Product or component type | Contactor |
Device short name | LC1F |
contactor application | Resistive load |
utilisation category | AC-1 |
Poles description | 2P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
[Uc] control circuit voltage | 380 V AC 40...400 Hz |
[Ie] rated operational current | 1000 A (at <40 °C) at <= 440 V AC AC-1 |
[Uimp] rated impulse withstand voltage | 8 kV |
---|---|
[Ith] conventional free air thermal current | 1000 A (at 40 °C) 1250 A |
Rated breaking capacity | 5040 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 5050 A 40 °C - 10 s 4400 A 40 °C - 30 s 3400 A 40 °C - 1 min 2200 A 40 °C - 3 min 1600 A 40 °C - 10 min |
Associated fuse rating | 1000 A gG at <= 440 V 630 A aM at <= 440 V |
Average impedance | 0.12 mOhm - Ith 1000 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole | 120 W AC-1 |
Overvoltage category | III |
power pole contact composition | 2 NO |
Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C) |
Mechanical durability | 5 Mcycles |
Inrush power in VA | 1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA | 22 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Maximum operating rate | 1200 cyc/h 55 °C |
Operating time | 40...80 ms closing 100...200 ms opening |
Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm Power circuit: bolted connection |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 58 N.m |
mounting support | Plate |
Heat dissipation | 20 W |
standards | JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 |
product certifications | CCC ABS UL RMRoS LROS (Lloyds register of shipping) DNV RINA CB BV |
Compatibility code | LC1F |
Control circuit type | AC at 40...400 Hz |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
height | 304 mm |
Width | 309 mm |
Depth | 255 mm |
Operating altitude | 3000 m without derating |
Net weight | 15.5 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Warranty | 18 months |
---|