var product_container_array = document.querySelectorAll("[data-zs-product-id]"); for(var i=0; i< product_container_array.length; i++) { var label_price_container=product_container_array[i].querySelector("[data-zs-label-price]"); if(label_price_container){ var selling_price_container=product_container_array[i].querySelector("[data-zs-selling-price]"); var label_price=Number(label_price_container.getAttribute("data-zs-label-price")); var selling_price=Number(selling_price_container.getAttribute("data-zs-selling-price")); var discounted_price=label_price - selling_price; var discount_percent=(discounted_price/label_price)*100; discount_percent=discount_percent.toFixed(1); /* Creating new p tag for showing discount */ var paragraph_elem=document.createElement("P"); var text_elem=document.createTextNode("Discount : "+discount_percent+"%"); paragraph_elem.style="margin: auto;font-size: initial;" ; paragraph_elem.appendChild(text_elem); label_price_container.insertAdjacentElement('afterend',paragraph_elem); } }
STANDARD SALES CORPORATION
0

RM17TG20 Ph Failure Rotatn 208-480v

PH FAILURE ROTATN 208-480VAC 2C/O


  • delivery time
    60 days
  • Quantity
RM17TG20  Ph Failure Rotatn 208-480v
RM17TG20  Ph Failure Rotatn 208-480v
RM17TG20  Ph Failure Rotatn 208-480v
RM17TG20  Ph Failure Rotatn 208-480v
RM17TG20  Ph Failure Rotatn 208-480v
Product Details
Main
Range of productHarmony Control Relays
Product or component type3-phase control relay
Relay typeControl relay
Product specific applicationFor 3-phase supply
Relay nameRM17TG
Relay monitored parametersPhase sequence
Phase failure detection (2 or more phase cut)
time delayWithout
Switching capacity in VA1250 VA
Measurement range208...440 V voltage AC
Contacts type and composition2 C/O
[Uc] control circuit voltage208...440 V
Complementary
Maximum switching voltage250 V AC
250 V DC
Minimum switching current10 mA at 5 V DC
Supply voltage limits183…484 V AC
Control circuit voltage limits- 12 % + 10 % Un
Power consumption in VA0…22 VA at 400 V AC 50 Hz
Voltage detection threshold< 100 V AC
control circuit frequency50...60 Hz +/- 10 %
Output contacts2 C/O
Nominal output current5 A
Measurement voltage limits183…484 V AC
delay at power up650 ms
Voltage range183...484 V
Response time<= 130 ms (in the event of a fault)
MarkingCE
Overvoltage categoryIII conforming to IEC 60664-1
Insulation resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5
> 500 MOhm at 500 V DC conforming to IEC 60664-1
[Ui] rated insulation voltage400 V conforming to IEC 60664-1
Supply frequency50/60 Hz +/- 10 %
Operating positionAny position without derating
Connections - terminalsScrew terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing plastic
Local signallingLED (yellow) for relay ON
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability10000 cycles
Mechanical durability30000000 cycles
Operating rate<= 360 operations/hour full load
Utilisation categoryAC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
Safety reliability dataB10d = 850000
MTTFd = 924.6 years
Width17.5 mm
Net weight0.13 kg
Environment
Electromagnetic compatibilityEmission standard for industrial environments conforming to IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Immunity for industrial environments conforming to IEC 61000-6-2
standardsIEC 60255-1
product certificationsGOST
C-Tick
UL
CSA
GL
Directives73/23/EEC - low voltage directive
89/336/EEC - electromagnetic compatibility
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-20…50 °C
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
Shock resistance15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Dielectric test voltage2 kV, 1 min AC 50 Hz
Non-dissipating shock wave4 kV
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.700 cm
Package 1 Width7.800 cm
Package 1 Length9.700 cm
Package 1 Weight98.000 g
Unit Type of Package 2S02
Number of Units in Package 248
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.150 kg
Unit Type of Package 3P06
Number of Units in Package 3768
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight87.204 kg
Contractual warranty
Warranty18 months

- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.