var product_container_array = document.querySelectorAll("[data-zs-product-id]"); for(var i=0; i< product_container_array.length; i++) { var label_price_container=product_container_array[i].querySelector("[data-zs-label-price]"); if(label_price_container){ var selling_price_container=product_container_array[i].querySelector("[data-zs-selling-price]"); var label_price=Number(label_price_container.getAttribute("data-zs-label-price")); var selling_price=Number(selling_price_container.getAttribute("data-zs-selling-price")); var discounted_price=label_price - selling_price; var discount_percent=(discounted_price/label_price)*100; discount_percent=discount_percent.toFixed(1); /* Creating new p tag for showing discount */ var paragraph_elem=document.createElement("P"); var text_elem=document.createTextNode("Discount : "+discount_percent+"%"); paragraph_elem.style="margin: auto;font-size: initial;" ; paragraph_elem.appendChild(text_elem); label_price_container.insertAdjacentElement('afterend',paragraph_elem); } }
STANDARD SALES CORPORATION
0

LC1F2654

4P 4 NO-AC-1 440V 350A with coil LX1/LX9 -24…1000V AC 40/400Hz



  • delivery time
    60 days
  • Quantity
LC1F2654
Product Details
Main
RangeTeSys
Product nameTeSys F
Product or component typeContactor
Device short nameLC1F
contactor applicationResistive load
utilisation categoryAC-1
Poles description4P
power pole contact composition4 NO
[Ie] rated operational current350 A (at <40 °C) at <= 440 V AC AC-1
Complementary
[Uc] control circuit voltage24...1000 V AC 40...400 Hz with LX1/LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V with LXE coil
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current350 A (at 40 °C)
Irms rated making capacity2650 A AC conforming to IEC 60947-4-1
Rated breaking capacity2120 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current2200 A 40 °C - 10 s
1230 A 40 °C - 30 s
950 A 40 °C - 1 min
620 A 40 °C - 3 min
480 A 40 °C - 10 min
Associated fuse rating315 A aM at <= 440 V
400 A gG at <= 440 V
Average impedance0.3 mOhm - Ith 350 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole37 W AC-1
Control circuit voltage limitsOperational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
Heat dissipation8 W
2.2…2.5 W
Operating time40...65 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
40...50 ms closing for with LX4 coil
40...65 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
Mounting supportPlate
StandardsIEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
EN 60947-1
EN 60947-4-1
product certificationsABS
CB
DNV
RMRoS
UL
CSA
RINA
LROS (Lloyds register of shipping)
BV
UKCA
Connections - terminalsPower circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 240 mm²
Power circuit: connector 1 cable(s) 240 mm²
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Tightening torquePower circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
Mechanical durability10 Mcycles
Inrush power in VA600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
655…803 VA (at 20 °C)with LX4 coil
300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
300…310 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
3.68…4.53 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate2400 cyc/h 55 °C
Compatibility codeLC1F
[Ue] rated operational voltage<= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V DC
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height203 mm
Width244.5 mm
Depth213 mm
Net weight8.54 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height24.000 cm
Package 1 Width24.400 cm
Package 1 Length28.600 cm
Package 1 Weight8.462 kg
Unit Type of Package 2P06
Number of Units in Package 210
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight93.660 kg
Contractual warranty
Warranty18 months













- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.